06/06/01 Datatek Applications Inc. 8
Make sure the module is in service and the
Local IP Address
indicated in this report
agrees with the
BiSync Host Interface
(IP address part) from the TN3270 Application
report in the previous section.
Now use the
vfy vport all
command to check the UMI virtual port settings:
<UMI> vfy vport all
Virtual Ports 1 - 32 :
Type ==> TCP Port 31000 w/Call Listen.
Service State ==> In Service.
Protocol ==> Synchronous.
Virtual Ports 33 - 504 :
Type ==> TCP Port 12345 w/Call Listen.
Service State ==> Out of Service.
Protocol ==> Synchronous.
There should be a group of receive-type virtual ports (indicated by “Call Listen”) using a
TCP port number which agrees with the
BiSync Host Interface
(port number part) from
the TN3270 Application report in the previous section. The protocol must be
synchronous and the virtual port group must be in service. Use the
vport
command to
change settings if needed. (If the virtual ports are not in service, they must be put in
service using
restore sam
on the BNS-2000 node. Refer to the
UMI User’s Manual
.
)