'7717URXEOHVKRRWLQJ*XLGH
06/06/01 Datatek Applications Inc. 14
3.4 Step 4 - Find UMI Virtual Port Associated with Client
Now go to the UMI console and run the
dc
command. This report will show the far-end
IP addresses and TCP port numbers of up to 504 UMI connections. Find the connection
associated with the IP address of the DT-6061 and TCP port number obtained in Step 3.
<UMI> dc
Active Connections:
.
VPort 2: connected to 192.168.8.250 port 2721
.
.
.
The report indicates that virtual port 2 on the UMI is connected to the TN3270
application on the DT-6061, and specifically to the session established by the PC client
in question. At this point the IP network connections from client to UMI have been
verified. Proceed to Step 5.
3.5 Step 5 - Find SAM504 Connection Associated with Client
This step will verify the connection between the UMI and BHI modules across the BNS-
2000 node. Using the information obtained in Step 4, we know that the call we are
attempting to trace is established on virtual port 2 of the UMI. From the previous
configuration checks we also know that virtual port 2 on the UMI appears to the node as
Board 1 Port 2 of a SAM 504 in slot 19 (where the UMI is located).