Datatek DT-6061 Manual do Utilizador Página 15

  • Descarregar
  • Adicionar aos meus manuais
  • Imprimir
Vista de página 14
'7717URXEOHVKRRWLQJ*XLGH
06/06/01 Datatek Applications Inc. 15
From the node console run the
dis conn mod <slot#>
command.
CC0> dis conn mod 19
01-05-08 14:33:41 NODE=WOODY
M display connections mod 19
MODULE: 19
---------------
CH/PT CU/TM GROUP PKT CNT STATE TO MOD CH/PT CU/TM GROUP PK
BOARD (+ = PDD BOARD
CS/LCH or PVC, CS/LCH
PT/LCH # = RRC) PT/LCH
PT/DLCI PT/DLCI
1 **** 330668 ACTIVE
3 **** 83 ACTIVE
8/1 1 sambsc 11555 +IDLE
9/2 1 sambsc 16381 +TALKING 26 2005 host26
10/3 1 sambsc 0 +IDLE
11/4 1 sambsc 0 +IDLE
The report shows that there is an active PDD connection (“+TALKING”) from port 2 of
“board 1” of module 19 to module 26 and destination group “host26”, which agrees with
the PDD information which was verified earlier (sec. 2.1.4). This completes the steps
needed to trace a TN3270 session from the client PC to the BHI terminal port.
Vista de página 14
1 2 ... 10 11 12 13 14 15 16 17 18 19 20

Comentários a estes Manuais

Sem comentários